Thursday, 13 June 2013

LED license lights



Doska plosnych spojov je siroka, na druhej fotke vidno lepsie ako by branila kontaktom v kontakte :). Zvolil som preto "trvale namontovanie" pomocou 1.5mm medeneho drotu. Povodne kontakty su medene takze nieje problem s naletovanim. Predpokladam, ze tieto svetla budu svietit este dlho po tom ako sa auto rozpadne, urobil som ich nerozoberatelne a vsetky diery zatmelil ciernym akvaristickym silikonom.
custom "tips", are shortened by myself, DPS is to wide, so this is not the right way ...
not good at all :)
it's fit under contacts,perfect
hole need to be covered, sometimes water come in ....
holes covered
soldering copper wire
jobe done

Tuesday, 11 June 2013

restoration of handlers

8D9 827 576
removing oxidation

removing oxidation

sanding

sanding
after cleaning old painting, apply a very thin layer of special base for aluminium ( http://www.tradix.sk/alkyton/galvinol/ )

filler and base paint

first black layer


finished

with hibryd LED lights, and some ugly screwes ... holes in glass are cracked



It's not perfect, oxidation take a lot of material ....
sealed back door lock
Back door lock was not functional for long time, thief with screwdriver make this :/. I field it with liquid metal (some sort of epoxi + metal powder). After one day, sanding and painting, job done.




seat regulator repair

cold solder joints on this diod
reseolder this joint

Monday, 24 September 2012

nefunkcny WD3200BMVV


hdparm -t /dev/sdc

/dev/sdc:
 Timing buffered disk reads: 228 MB in  3.01 seconds =  75.86 MB/sec
hdparm -i /dev/sdc

/dev/sdc:

 Model=WDC WD3200BMVV-11GNWS0, FwRev=01.01A01, SerialNo=WD-WX51A60Y0357
 Config={ HardSect NotMFM HdSw>15uSec SpinMotCtl Fixed DTR>5Mbs FmtGapReq }
 RawCHS=16383/16/63, TrkSize=0, SectSize=0, ECCbytes=50
 BuffType=unknown, BuffSize=8192kB, MaxMultSect=16, MultSect=off
 CurCHS=16383/16/63, CurSects=16514064, LBA=yes, LBAsects=625142448
 IORDY=on/off, tPIO={min:120,w/IORDY:120}, tDMA={min:120,rec:120}
 PIO modes:  pio0 pio3 pio4
 DMA modes:  mdma0 mdma1 mdma2
 UDMA modes: udma0 udma1 udma2 udma3 udma4 udma5 *udma6
 AdvancedPM=yes: unknown setting WriteCache=enabled
 Drive conforms to: Unspecified:  ATA/ATAPI-1,2,3,4,5,6,7

 * signifies the current active mode

hdparm -I /dev/sdc

/dev/sdc:

ATA device, with non-removable media
Model Number:       WDC WD3200BMVV-11GNWS0                
Serial Number:      WD-WX51A60Y0357
Firmware Revision:  01.01A01
Transport:          Serial, SATA 1.0a, SATA II Extensions, SATA Rev 2.5, SATA Rev 2.6
Standards:
Supported: 8 7 6 5
Likely used: 8
Configuration:
Logical max current
cylinders 16383 16383
heads 16 16
sectors/track 63 63
--
CHS current addressable sectors:   16514064
LBA    user addressable sectors:  268435455
LBA48  user addressable sectors:  625142448
Logical  Sector size:                   512 bytes
Physical Sector size:                  4096 bytes
Logical Sector-0 offset:                  0 bytes
device size with M = 1024*1024:      305245 MBytes
device size with M = 1000*1000:      320072 MBytes (320 GB)
cache/buffer size  = 8192 KBytes
Nominal Media Rotation Rate: 5400
Capabilities:
LBA, IORDY(can be disabled)
Queue depth: 32
Standby timer values: spec'd by Standard, with device specific minimum
R/W multiple sector transfer: Max = 16 Current = 0
Advanced power management level: 254
Recommended acoustic management value: 128, current value: 254
DMA: mdma0 mdma1 mdma2 udma0 udma1 udma2 udma3 udma4 udma5 *udma6
    Cycle time: min=120ns recommended=120ns
PIO: pio0 pio1 pio2 pio3 pio4
    Cycle time: no flow control=120ns  IORDY flow control=120ns
Commands/features:
Enabled Supported:
  * SMART feature set
    Security Mode feature set
  * Power Management feature set
  * Write cache
  * Look-ahead
  * Host Protected Area feature set
  * WRITE_BUFFER command
  * READ_BUFFER command
  * NOP cmd
  * DOWNLOAD_MICROCODE
  * Advanced Power Management feature set
    SET_MAX security extension
  * Automatic Acoustic Management feature set
  * 48-bit Address feature set
  * Device Configuration Overlay feature set
  * Mandatory FLUSH_CACHE
  * FLUSH_CACHE_EXT
  * SMART error logging
  * SMART self-test
  * General Purpose Logging feature set
  * 64-bit World wide name
  * IDLE_IMMEDIATE with UNLOAD
  * {READ,WRITE}_DMA_EXT_GPL commands
  * Segmented DOWNLOAD_MICROCODE
  * Gen1 signaling speed (1.5Gb/s)
  * Gen2 signaling speed (3.0Gb/s)
  * Native Command Queueing (NCQ)
  * Host-initiated interface power management
  * Phy event counters
  * Idle-Unload when NCQ is active
  * NCQ priority information
  * DMA Setup Auto-Activate optimization
    Device-initiated interface power management
  * Software settings preservation
  * SMART Command Transport (SCT) feature set
  * SCT Features Control (AC4)
  * SCT Data Tables (AC5)
    unknown 206[12] (vendor specific)
    unknown 206[13] (vendor specific)
    unknown 206[14] (vendor specific)
Security:
Master password revision code = 65534
supported
not enabled
not locked
not frozen
not expired: security count
supported: enhanced erase
104min for SECURITY ERASE UNIT. 104min for ENHANCED SECURITY ERASE UNIT.
Logical Unit WWN Device Identifier: 50014ee102ebfdca
NAA : 5
IEEE OUI : 0014ee
Unique ID : 102ebfdca
Checksum: correct